Specializing in Fluid Measurement and Conveyance Projects Since 2008
Pressure regulators alone cannot deliver repeatable flow. Manual valves drift. Fixed orifices cannot adapt.
The GMFC-T2 is an intelligent, high-precision mass flow controller built for industrial special gas applications.
It combines high-speed sampling, digital compensation algorithms, an imported electromagnetic proportional valve, a 316L stainless steel gas circuit seat, and a high-precision flow sensor – delivering high accuracy, fast response, and stable performance in one compact instrument.
| Your Challenge | GMFC-T2 Answer |
|---|---|
| Oxygen regulation | 316L stainless steel gas circuit – compatible with oxygen and oxidizing gases |
| Specialty industrial gases | Designed for industrial special gas applications – stable, accurate, reliable |
| Micro flow control | 0~10 SLM range; resolution as low as 0.01 SCCM – precise control at the micro scale |
| Fast process changes | Response time ≤1 second – keeps up with dynamic process steps |
| High accuracy requirements | 1% F.S. precision – repeatable, dependable flow control |
| Multiple signal interfaces | 4~20mA, 0~5V analog, RS485 digital – integrates with any control system |
| Local operation | Industrial-grade LCD touch screen – flow setting, instantaneous flow, cumulative flow display |
| Compact installations | Small size, low pressure drop – fits into tight gas panels and OEM equipment |
| System stability | Digital compensation algorithms – stable output across pressure and temperature variations |
| Control Type | Limitation | GMFC-T2 Advantage |
|---|---|---|
| Pressure regulator | Controls pressure, not flow – flow varies with downstream conditions | Direct mass flow control – flow stays where you set it |
| Manual needle valve | Requires constant adjustment, drifts with temperature and pressure | Automatic, stable, repeatable – set it and trust it |
| Fixed orifice | One flow rate only – cannot adapt to process changes | Adjustable setpoint, wide range, fast response |
| Mass flow meter only | Measures but does not control – needs separate valve | Integrated control valve and sensor – one instrument, closed-loop control |
| Parameter | Value |
|---|---|
| Product Name | Gas Mass Flow Controller |
| Model | GMFC-T2 |
| Precision | 1% F.S. |
| Flow Range | 0 ~ 10 SLM |
| Work Pressure | 0 ~ 1 MPa |
| Operating Temperature | 0 ~ 50°C |
| Resolution | Lowest 0.01 SCCM |
| Response Time | ≤1 s |
| Current Signal | 4~20mA |
| Analog Output | 0~5V (optional) |
| Digital Communication | RS485 |
| Display | Industrial-grade LCD touch screen |
| Display Functions | Flow setting, instantaneous flow, cumulative flow |
| Gas Circuit Material | 316L stainless steel |
| Valve Type | Imported electromagnetic proportional valve |
| Special Feature | High-speed sampling, digital compensation algorithms |
| Application | Oxygen, industrial special gases |
| Feature | What It Means for You |
|---|---|
| 1% F.S. precision | Repeatable flow control – batch after batch, run after run |
| 0.01 SCCM resolution | Micro-flow control for delicate processes and small-scale reactions |
| ≤1 second response | Keeps up with rapid process changes and pulsed flow requirements |
| 316L stainless steel gas circuit | Compatible with oxygen, oxidizing gases, and high-purity gases |
| Imported electromagnetic proportional valve | Fast, precise, reliable flow regulation |
| High-speed sampling + digital compensation | Stable output despite pressure and temperature variations |
| LCD touch screen | Local operation – set flow, view instantaneous and cumulative flow |
| Multiple signal options | 4~20mA, 0~5V, RS485 – connects to any PLC, DCS, or SCADA |
| Low pressure drop | Minimizes supply pressure requirements – saves energy |
| Compact size | Easy integration into OEM equipment and retrofits |
| Industry | Application | Why GMFC-T2 |
|---|---|---|
| Medical and Healthcare | Oxygen therapy, ventilator gas mixing, anesthesia | Accurate oxygen control, 316L construction, reliable |
| Industrial Gas | Specialty gas blending, cylinder filling, gas distribution | Wide gas compatibility, precise control |
| Chemical and Petrochemical | Reaction gas dosing, catalyst research, gas mixing | Stable output, fast response, digital communication |
| Semiconductor and Electronics | Process gas control, purge gas, carrier gas | High precision, micro flow, clean construction |
| Pharmaceutical | Fermentation gas control, nitrogen blanketing | Accurate, traceable, reliable |
| Metallurgy | Oxygen enrichment, shielding gas control | High accuracy, stable flow |
| Environmental | Calibration gas blending, emissions monitoring | Precise ratio control, RS485 integration |
| Laboratory and R&D | Microreactor feed, gas chromatography, test rigs | 0.01 SCCM resolution, fast response |
Would you rather adjust a valve by hand – or set a flow and trust it?
Manual adjustment drifts. Pressure regulators cannot control flow. Fixed orifices cannot adapt.
Closed-loop mass flow control keeps your process where you set it.
The GMFC-T2 gives you the control you need.
Ready to specify the GMFC-T2 for your gas system?
Contact us with your gas type, flow range, pressure, temperature, and signal requirements. We'll recommend the right configuration and provide a quote within 24 hours.
